DUAL INTEGRATED
CONNECTION
W
I
I
A
L
D
Code
Model
Country
Cylinder
connection
Standard
reference
Cartridge
connection
13005017001
K-AZ200-50/BN2
IT
W 21.7 x 1/14” M
UN 11144-5
M10x1
13005017005
K-AZ200-50/BN2-D
F-B-P-E
Ø 21.7 x 1.814 F
NF E 29-650/C
M10x1
SPARE PARTS
AND
13005017008
K-AZ200-50/BN2-E
GB
G 5/8” M
BS 341 nr.3
-
ACCESSORIES
PAGE 41
13005017009
K-AZ200-50/BN2-C
D
W 24.32 x 1/14” F
DIN 477 nr.10
M10x1
Max output pressure
4,8 MPa
Dimensions
360 x 320 x 120 mm
Comply to
CE n. 1516 2007
Code
Model
Description
09053011
Calibration report ref. Accredia for checking gauge
Code
Model
Capacity
Min. Qty
09001080
GAS CONTROL
400 ml
10
Ref
Code
Model
Capacity
A
11001060
BN2/1-TPED
Disposable
950 cc
B
11003011
BAZ50/1
Rechargeable
5l
A
11001060
12
320 x 250 x 330 mm
15,50 kg
B
11003011
-
550 x 150 x 150 mm
8,80 kg
PRESSURIZATION - TEST SYSTEMS
NITROGEN
N
2
K-AZ200-50/BN2
Nitrogen kit
Suitable for:
• Testing for leaks in pressure of HVAC systems.
• Flushing of HVAC systems.
• Fluxing during soldering in HVAC systems.
• Pressure switches and gauges calibration.
Kit includes:
• Nitrogen regulator serie AZ200-50 with dual integrated connection for cartridges and bottles.
• Ø80 gauge, class 1.0 with defined sectors, positioning indicator and calibration screw.
• Flexible hose 1/4” SAE , 900 mm + 200 mm.
• Nitrogen bottle 950 cc- 110 bar - TPED.
COMMISSIONREGULATION(EC) NO. 1516/2007
ARTICLE 8 - Repair of leakage
Technical features
Regulator inlet pressure
Connections
Weight
Calibration
20 MPa
1/4” SAE
4,5 kg
1. The operator shall ensure that the repair is carried out
by personnel certified to undertake that specific activity.
Prior to repair, a pump-down or recovery shall be carried
out, where necessary.
2. The operator shall ensure that a leakage test with Oxygen
Free Nitrogen (OFN) or another suitable pressure testing
and drying gas is carried out where necessary, followed
by evacuation, recharge and leakage test. Prior to pressure
testing with Oxygen Free Nitrogen (OFN) or another
suitable pressure testing gas, fluorinated greenhouse
gases shall be recovered from the whole application where
necessary.
NITROGEN CARTRIDGES AND CYLINDERS
Rif Code
Min. Qty
Dimensions
Weight
13005017016
K-AZ200-50/BN2/RT
Nitrogen kit with calibration report
T
H
• 1 adapter RG180/5-4 (5/16” SAE F x 1/4” SAE M).
• Sturdy plastic carrying case.
A
B
SPRAY LEAK DETECTOR
Code
Dimensions
38
09001080
340 x 140 x 220 mm
4,8 Kg
Weight.