INSTRUMENTS
INCLUDED
R32
ELD-H
Electronic leak detector
• Lightweight and ergonomic design.
• Both visual and audible leak detection signal.
• Simple, one button operation.
• Two sensitivity modes.
• Low battery indicator.
• Automatic power-off to conserve battery life.
INCLUDED
R1234ze
Code
Model
Dimensions
Weight
09001081
ELD-H
310 x 210 x 80 mm
0,9 kg
CFC
HFC
Detects ALL halogenated refrigerants, including:
R12-R11-R500-R503
R134A-R404A-R125-R407C-R507-R410A-R32
CE N 1516/2007: METHODS OF DIRECT MEASUREMENT
ARTICLE 6
HCFC
R22-R123-R124-R502
HFO
R1234yf and R1234ze
Technical features
Gas detection devices referred to in paragraph 1(a) shall be checked every 12 months to ensure
their proper functioning. The sensitivity of portable gas detection devices shall be at least five
grams per year.
Calibration
Spare parts
Code
Model
Description
09053009005
Calibration report for leak detector
09001081001
ELD-H/RT
Leak detector with calibration report
Technology
Negative crown
Maximum sensitivity
3 g/year
Calibration
automatic
Warm-up time
<2 seconds
Response time
instant
Probe Length
30 cm
Power supply
2x 1,5V alkaline batteries AA
Batteries life
40 hours
Compliance
CE n. 1516 2007
Code
Model
Description
09050073
ELS-H
Sensing tip for ELD-H