DATI TECNICI

VENTILAZIONE RESIDENZIALE

A

PRODOTTI

UNITÀ DI

MISURA

VORT HR 260 DH

VORT HR 260 DH RC

VORT HR 500 DH

VORT HR 500 DH RC

CODICE

45091

45092

45093

45094

ALIMENTAZIONE

V/Hz

230/50

230/50

230/50

230/50

POTENZA ASSORBITA VENTILATORE MANDATA

W

(min/nom/max)

10/30/86

10/30/86

30/60/130

30/60/130

POTENZA ASSORBITA VENTILATORE RIPRESA

W

(min/nom/max)

11/22/43

11/22/43

22/44/68

22/44/68

POTENZA FRIGO TOTALE IN AMBIENTE

W

1380

1380

2820

2820

POTENZA NOMINALE ASSORBITA COMPRESSORE

W

340

340

480

480

POTENZA TERMICA INVERNALE RECUPERATA

W

950

950

1850

1850

TIPO DI REFRIGERANTE

R134A

R134A

R134A

R134A

CAPACITÀ DI DEUMIDIFICAZIONE UTILE

l/24h

30.1

30.1

61.8

61.8

EFFICIENZA NOMINALE ESTIVA RECUPERATA

%

70

70

70

70

EFFICIENZA NOMINALE INVERNALE RECUPERATA

%

90

90

90

90

PERDITE DI CARICO CIRCUITO IDRAULICO

kPA

(nom)

38

38

35

35

PORTATA D’ACQUA BATTERIA

l/h

(min/nom/max)

150/250/400

150/250/400

200/350/600

200/350/600

PORTATA D’ARIA MANDATA ESTIVA

m

3

/h

260

260

500

500

PORTATA D’ARIA MANDATA INVERNO

m

3

/h

0-130

0-130

0-250

0-250

POTENZA SONORA

Lw dB(A)

47

47

52

52

PRESSIONE SONORA

Lp dB(A) 3m

39

39

44

44

PREVALENZA UTILE VENTILATORE DI MANDATA

Pa

(nom/max)

50/140

50/140

50/140

50/140

PREVALENZA UTILE VENTILATORE DI RIPRESA

Pa

(nom/max)

50/140

50/140

50/140

50/140

PESO

Kg

60

60

80

80

205

V

E

N

T

I

L

A

Z

I

O

N

E

R

E

S

I

D

E

N

Z

I

A

L

E