Dima da posizionare all’interno dell’armadio
2
2
1
8
0
1
4
9
5
5
8
7
7
5
7
6
4
5
0
3
2
,
5
3
2
3
9
Dima da posizionare sotto l’armadio
Le dime sono scaricabili dal sito baxi.it alla sezione prodotti.
LIQUIDO REFRIGERANTE
ALYA E/H 12 kW (R3/8'')
ALYA E/H 8-10 kW (R3/8'')
ALYA E/H 4-6 kW (R1/4")
MANDATA
RISC./RAFFR.
(A/B)
A/B A/B/C
MANDATA
RISC. BT2
(C)
RITORNO
RISC. BT1
(C)
A/B/C
RITORNO
RAFFR.
(A/B)
A/B/C
RITORNO
RISC.
(A/B)
A/B/C
RITORNO
RISC. BT2
(C)
MANDATA DAL
SOLARE (A/B/C)
RITORNO AL
MANDATA
SOLARE (A/B/C)
RISC. AT (C)
USCITA
SANITARIO (A/B/C)
A/B/C
GAS
(A/B/C)
A/B/C
A/B/C
RICIRCOLO
(A/B/C)
ENTRATA
SANITARIO (A/B/C)
A/B/C
SCARICO
VALVOLA DI
SICUREZZA
RITORNO
RISC. AT (C)
C
CONTROLLO
REMOTO (A/B/C)
A/B/C
ALIM. 230V
(A/B/C)
A/B/C
A/B/C A/B/C
C
SCARICO
CONDENSA
(A/B/C)
A/B/C
(A/B/C)
A/B
MANDATA
RISC. BT1
(C)
C
GAS REFRIGERANTE
ALYA E/H 12 kW (R5/8'')
ALYA E/H 8-10 kW (R5/8'')
ALYA E/H 4-6 kW (R5/8")
A/B
MANDATA
DAL SOLARE
(A/B)
A/B
RITORNO
AL SOLARE
(A/B)
MANDATA
DAL SOLARE
B/C
A=CSI IN ALYA E / H
B=CSI IN AURIGA E / H
C=DUO TEC IN SOLAR
SCARICO
VALVOLA DI
SICUREZZA
(A/B/C)
A/B/C
CONTROLLO
REMOTO
(A/B/C)
A/B/C
A/B/C
ALIM. 230V
(A/B/C)
(C)
A/B/C
SCARICO
CONDENSA
(A/B/C)
MANDATA
RISC. AT
(C)
B/C
C
USCITA
SANITARIO
(A/B/C)
A/B/C
MANDATA
RAFFR.
(A/B)
A/B/C
MANDATA
RISC. BT2
(C)
GAS
(A/B/C)
A/B/C
A/B/C
RICIRCOLO
(A/B/C)
ENTRATA
SANITARIO
(A/B/C)
A/B/C
RITORNO
RAFFR.
(A/B)
A/B/C
RITORNO
RISC. BT1
(C)
RITORNO
RISC. AT
(C)
C
RITORNO
RISC.
(A/B)
A/B/C
RITORNO
RISC. BT2
(C)
LIQUIDO REFRIGERANTE
ALYA E/H 12 kW (R3/8'')
ALYA E/H 8-10 kW (R3/8'')
ALYA E/H 4-6 kW (R1/4")
GAS REFRIGERANTE
ALYA E/H 12 kW (R5/8'')
ALYA E/H 8-10 kW (R5/8'')
ALYA E/H 4-6 kW (R5/8")
A
A
(A/B)
A/B/C
MANDATA
RISC. BT1
(C)
RITORNO
AL SOLARE
(C)
MANDATA
RISC./RAFFR.
118
49 55 40 40 80
80 40 40 52 76
B
B
C
C
75
90
B
B
B
A
B
A
B
A
B
27
B
B
B
A
B
A
B
B
B
C
B
B
A
B
A
65
55
670
52 76
B
B
A
B
B
A
80
66
A= ø35
B= ø40
C= ø50
C
25
94
80
B
B
B
7
3
4
5
4
4
5
0
LIQUIDO REFRIGERANTE
ALYA E/H 12 kW (R3/8'')
ALYA E/H 8-10 kW (R3/8'')
ALYA E/H 4-6 kW (R1/4")
MANDATA
RISC. BT1
(C)
40
MANDATA
RAFFR.
(A/B)
RICIRCOLO
RAFFR.
(A/B/C)
(A/B)
A/B
A/B
MANDATA
DAL SOLARE
(C)
MANDATA
DAL SOLARE
(A/B)
RITORNO
A
L
( A
S
/
O
B
L
)
A
R
E
B/C
RITORNO
ALLA POMPA
DI CALORE
B/C
RITORNO
AL SOLARE
(C)
MANDATA
DALLA POMPA
DI CALORE
A/B/C
SCARICO
CONDENSA
(A/B/C)
RISC. AT
(C)
C
MANDATA
RISC./RAFFR.
(A/B)
A/B/C
USCITA
SANITARIO
(A/B/C)
A/B/C
MANDATA
RAFFR.
(A/B)
A/B/C
MANDATA
RISC. BT2
(C)
66
GAS
(A/B/C)
A/B/C
A/B/C
RICIRCOLO
(A/B/C)
ENTRATA
RITORNO
SANITARIO
RISC. AT
(A/B/C)
(C)
A/B/C
C
RITORNO
RITORNO
RAFFR.
RISC./RAFFR.
(A/B)
(A/B)
A/B/C
A/B/C
RITORNO
RITORNO
RISC. BT1
RISC. BT2
(C)
(C)
LIQUIDO REFRIGERANTE
ALYA E/H 12 kW (R3/8'')
ALYA E/H 8-10 kW (R3/8'')
ALYA E/H 4-6 kW (R1/4")
GAS REFRIGERANTE
ALYA E/H 12 kW (R5/8'')
ALYA E/H 8-10 kW (R5/8'')
ALYA E/H 4-6 kW (R5/8")
MANDATA
DAL SOLARE
(A/B/C)
A/B/C
RITORNO
AL SOLARE
(A/B/C)
A/B/C
MANDATA
RISC. AT
(C)
C
USCITA
SANITARIO CSI IN E:
(A/B/C) NON PRESENTE
GAS
(A/B/C)
ENTRATA
SANITARIO
(A/B/C)
SCARICO
A/B/C
VALVOLA DI
SICUREZZA
RITORNO
RISC. AT
(C)
C
CONTROLLO
REMOTO
(A/B/C)
A/B/C
ALIM. 230V
(A/B/C)
A/B/C
7728798
52
76
SCARICO
VALVOLA DI
SICUREZZA
(A/B/C)
A/B/C
CONTROLLO
REMOTO
(A/B/C)
A/B/C
A/B/C
ALIM. 230V
(A/B/C)
RITORNO
ALLA POMPA
DI CALORE
MANDATA
DALLA POMPA
DI CALORE
MANDATA
A/B/C
RISC./RAFFR.
(A/B)
A/B/C
A/B/C
RITORNO
RISC.
(A/B)
A/B/C
RITORNO
RISC. BT2
(C)
(B)
A/B
(B)
A/B
GAS REFRIGERANTE
ALYA E/H 12 kW (R5/8'')
ALYA E/H 8-10 kW (R5/8'')
ALYA E/H 4-6 kW (R5/8")
49
55
80
80
80
A
A
MANDATA
RISC. BT1
(C)
A/B/C
MANDATA
RISC. BT2
(C)
A/B/C
(
B
)
(
B
)
MANDATA
SCARICO
CONDENSA
(A/B/C)
A/B/C
A/B/C
(A/B/C)
27
65
55
80
80
80
80
52
76
RITORNO
RISC. BT1
(C)
A/B/C
RITORNO
40
Scarico fumi
CSI 382
CSI IN E:
NON PRESENTE
289
4
5
9
4
5
5
5
1
1
4
0
1
9
4
7
1
.
5
7
5
7
6
8
0
6
5
3
9
Scarico fumi
DUO-TEC IN SOLAR
330
150
A=CSI IN ALYA E / H
B=CSI IN AURIGA E / H
C=DUO TEC IN SOLAR
Altezza scarico fumi
da pavimento H=2170
153
1000
2
1
7
0
4
0
0
m
i
n
1
5
0
80
D
i
s
t
a
n
z
a
m
i
n
i
m
a
d
a
l
m
u
r
o
l
a
t
e
r
a
l
e
:
1
5
0
m
m
21