SOFI

®

HC

Il radiatore ventilato caldo & freddo

LA SOLUZIONE COMPLETA PER LA

CASA EFFICIENTE

Solare Fotovoltaico

Solare Termico

Acqua calda sanitaria

Serbatoio ACS

Comando remoto

Pompa di calore

Radiatori

ad alta efficienza

Radiatori ventilati Caldo-Freddo

SOFI

®

HC 800 x 610 thermal output (∆T 50)

Sofi Or 800*610 rese termiche

Volano Termico

Standard EN 16430 - Fan Assisted Radiators/Convectors

Following the scheme of Case 1

3

2

1

0

6000

5000

4000

3000

2000

1000

0

20

25

30

35

40

45

50

55

60

65

Delta T

W

a

t

t

27

Fan

speed

V3

V2

V1

v0

Φ

MFS

=

K

m_MFS

· (ΔT)

Insert values calculated at the end of the test. Data Input (yellow field)

test n° :

Value of constant: K

m_MFS

Value of exponent: n

_MFS

Nominal Thermal Output value: Φ

ΔT50_MFS

3392.5

n_

MFS

17851

36.61075

1.15771

Rel.17850-851 Elab_dati CORDIVARI FAN_2

W

Thermal Output Δt=30 K:

Thermal Output Δt=60 K:

1878 W

4190 W

17851

T

E