Assorbi-
mento
Compres-
sore
TL3CN
TL4CN
TL5CN
NL7CN
NL9CN
NL9CN
SC10CNX
SC12CNX
SC12CNX
SC15CNX
SC15CNX
SC18CNX
SC18CNX
SC12CNX.2
SC15CNX.2
SC18CNX.2
SC21CNX.2
SC10MNX
SC12MNX
SC15MNX
SC18MNX
Compres-
sore
Codice
102H4380
102H4490
102H4590
105H6756
105H6856
105H6780
104H8065
104H8265
104H8267
104H8565
104H8576
104H8865
104H8867
104H8266
104H8566
104H8866
104H8166
104H8075
104H8275
104H8575
104H8875
Codice
32 °C
38 °C
43 °C
F1 F1
F1 F1
F1 F1
F1 F2
F2 F2*
F2 F2*
F2 F2
F2 F2
F2 F2
F2 F2
F2 F2
F2 F2
F2 F2
F2
–
F2
–
F2
–
F2
–
–
F2
–
F2
–
F2
–
F2
-40
-35 -30
-25
-23,3 -20 -15 -10 -6,7 -5
0
5
7,2 10
108 128 161 200 228 244 294
143 166 205 250 283 302 360
198 230 283 345 391 416 496
315 368 458 561 637 679 814
364 423 526 643 730 778 930
364 423 526 643 730 778 930
355 420 531 660 748 809 979
462 540 678 846 976 1050 1293 1582
–
462 540 678 846 976 1050 1293 1582
–
601 707 887 1093 1245 1328 1594 1894
–
601 707 887 1093 1245 1328 1594 1894
–
700 824 1033 1272 1448 1543 1849 2193
–
700 824 1033 1272 1448 1543 1849 2193
–
493 57
8
72
5
895
–
–
–
–
–
609 71
4
90
0
112
0
–
–
–
–
–
747 86
3
10571273
–
–
–
–
–
891 102012331471
–
–
–
–
–
368 445 575 724 834 894 1088 1307 1412 1554
490 582 738 918 1050 1123 1356 1620 1747 1918
611 715 893 1098 1249 1332 1598 1900 2044 2239
730 844 1039 1263 1428 1519 1810 2140 2298 2512
Capacità (BTU/h) alle condizioni ASHRAE
Temperatura di evaporazione [°F]
-25 -10 [cm
3
]
38
54
75
99
351
–
426
–
586
–
965
–
1102
–
1102
–
1172
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
108 135
127 162
162 211
221 291
250 334
250 334
274 362
344 456
344 456
420 560
420 560
500 707
500 707
379 502
445 610
541 682
623 855
295 405
392 503
–
597
544 709
3,13
3,86
5,08
7,27
8,35
8,35
10,29
12,87
12,87
15,28
15,28
17,69
17,69
12,87
15,28
17,69
20,95
10,29
12,87
15,28
17,69
F1
F1
F1
F1
F1
F1
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
–
–
–
–
F1 F1 F1
F1 F1 F1
F1 F1 F1
F1 F1 F1
F1 F1 F1
F1 F1 F1
F2 F2 F2
F2 F2 F2
F2 F2 F2
F2 F2 F2
F2 F2 F2
F2 F2 F2
F2 F2 F2
–
F2
–
–
F2
–
–
F2
–
–
F2
–
F2
–
F2
F2
–
F2
F2
–
F2
F2
–
F2
57
78
81 109
118 166
138 194
138 194
126 179
178 250
178 250
195 297
195 297
219 341
219 341
186 258
252 332
244 384
339 492
–
149
–
224
103 132
143 183
223 290
259 335
259 335
245 325
331 426
331 426
415 550
415 550
480 640
480 640
346 453
434 560
531 689
654 828
234 332
327 446
–
–
–
–
Capacità (W) alle condizioni EN12900 / CECOMAF
Temperatura di evaporazione [°C]
elettrico
Cilin-
[W]
drata
Compressore raccomandato
alla temperatura ambiente
1
1
5
V
6
0
H
z
A
l
i
m
e
n
t
a
z
i
o
n
e
M
B
P
H
S
T
L
B
P
H
S
T
2
2
0
-
2
4
0
V
5
0
H
z
L
B
P
/
M
B
P
L
B
P
/
M
B
P
L
S
T
/
H
S
T
A
l
i
m
e
n
t
a
z
i
o
n
e
A
p
p
l
i
c
a
z
i
o
n
e
T
i
p
o
m
o
t
o
r
e
L
B
P
/
M
B
P
H
S
T
A
p
p
l
i
c
a
z
i
o
n
e
M
o
t
o
r
t
y
p
e
s
H
S
T
L
B
P
M
B
P
L
B
P
M
B
P
L
B
P
M
B
P
L
B
P
M
B
P
L
B
P
M
B
P
L
B
P
M
B
P
Applicazioni
RSIR =
RSCR =
CSIR =
CSR
=
LBP =
MBP =
HBP =
Low Back Pressure
Medium Back Pressure
High Back Pressure
Resistant Start Induction Run
Resistant Start Capacitor Run
Capacitor Start Induction Run
Capacitor Start Run
SC10CNX.2 104H7070 – 204 571 1007
SC12CNX.2 104H7270 268 589 1005 1500
1359 1523 2133 2848 3167 3682 4649 5762 5882 6378 366 495 573
0,63
F2 F2 F2 F2 F2 F2
1899 2085 2776 3587 3949 4533 5627 6887 7022 7583 456 606 731
0,78
F2 F2 F2 F2 F2 F2
Tipi di motore
Raffredamento compressore
Dispositivi di avviamento
LST
= Low Starting Torque
LST is used with capillary tube control and pressure equalizing. (Pressure equalizing may exceed 10
minutes). The PTC starting device requires 5 minutes cooling before each start.
HST
= HST consisting of relay and starting capacitor is used for expansion valve control or for
capillary tube control without pressure equalizing.
S =
O =
F
1
=
F
2
=
* =
Static cooling normally sufficient
Oil cooling
Fan cooling 1,5 m/s
(compressor compartment temp. equal to ambient temperature)
Fan cooling 3,0 m/s necessary
Run capacitor 4 μF compulsory in 43°C ambient
temperature at MBP conditions.
Condizioni di test
EN 12900-CECOMAF (220 V / 50 Hz)
Compressori: TL / NL / SC-CNX and CNX 2
Temperatura di condensazione: 45 °C
Temperatura ambiente: 32 °C
Temperatura di aspirazione gas: 32 °C
Temperatura del liquido: No sub cooling
Condizioni di test
EN 12900-MBP (220 V / 50 Hz)
Compressori: SC-MNX
Temperatura di condensazione: 45 °C
Temperatura ambiente: 32 °C
Temperatura di aspirazione gas: 20 °C
Temperatura del liquido: No sub cooling
Condizioni di test
ASHRAE-LBP (115 V / 60 Hz)
Compressori: SC-CNX 2
Temperatura di condensazione: 130 °F
Temperatura ambiente: 90 °F
Temperatura di aspirazione gas: 90 °F
Temperatura del liquido: 90 °F
–
–
–
675
-49 -40 -30 -20 -13 -10
0
10
14
20
30
40
41
45 -13 14 41 cu.inch
Assorbimento
elettrico [W]
Cilin-
drata
Raffreddamento com-
pressore raccoman-
dato a temperatura
ambiente
32 °C 38 °C 43 °C