Dati tecnici

HCFC / HFC / HC

Dati tecnici

Refrigerante

Tipo

Press. chiusura

regolabile

press. controllo

[bar]

Pressione

d’esercizio max.

PS

[bar]

Pressione di

prova max. PB

[bar]

Mezzi

Pressione

massima

d’esercizio PS

[bar]

WVO 10

4,0 – 22

2

)

26,4

60

16

HCFC / HFC / HC

3,5 – 16

WVFX 10

4,0 – 23

15,0 – 29,0

26,4

60

16

26,4

60

45,2

60

16

16

WVO 15

4,0 – 22

2

)

26,4

60

16

3,5 – 16,0

WVFX 15

4,0 – 23,0

15,0 – 29,0

26,4

29

16

26,4

29

Acqua fresca,

glicole, acqua

marina

16

45,2

60

16

3,5 – 16,0

WVFX 20

4,0 – 23,0

15,0 – 29,0

26,4

29

16

26,4

29

16

45,2

60

16

3,5 – 16,0

WVFX 25

4,0 – 23,0

15,0 – 29,0

26,4

29

16

26,4

29

16

45,2

60

16

WVFX 32

4,0 – 17,0

24,1

26,5

10

WVFX 40

4,0 – 17,0

24,1

26,5

10

HCFC / HFC /

HC / R717

WVS 32

2,2 – 19,0

26,4

29

Acqua dolce,

glicole

10

WVS 40

2,2 – 19,0

26,4

29

10

WVS 50

2,2 – 19,0

26,4

29

10

WVS 65

2,2 – 19,0

26,4

29

10

WVS 80

2,2 – 19,0

26,4

29

10

WVS 100

2,2 – 19,0

26,4

29

10

Lato liquido

Pressione di

prova max. PS

[bar]

Valore K

v

1

)

[m

3

/h]

24

1,4

24

1,4

24

1,4

24

1,4

24

1,4

24

1,9

24

1,9

24

1,9

24

3,4

24

3,4

24

3,4

24

5,5

24

5,5

24

5,5

10

11,0

10

11,0

16

12,5

16

21,0

16

32,0

16

45,0

16

80,0

16

125,0

1

) Il valore K

v

indica la portata in [m3/h] a ua perdita di carico attraverso la valvola di 1 bar, ρ = 1000 kg/m3.

2

) Ampiezza campo di regolazione della pressione max. 6 bar.

Campo temperatura mezzo:

WVFX 10 – WVFX 25: -25 – 130 °C

WVFX 32 – WVFX 40: -25 – 90 °C

WVS50–WVS100:-25–90°C

Pressione differenziale di apertura:

WVO10–25:0–10bar

WVFX10–WVFX40:0–10bar

WVS32–WVFX40:0,5–4bar

WVS50–WVS100:0,3–4bar

150 Quick Selection Catalogue