V

e

l

o

c

i

t

à

d

e

l

l

'

a

r

A

i

r

s

p

e

e

d

(

m

4.0

4.0

3.0

3.0

2.0

2.0

A PARET

E

1.0

1.0

0.0

0.0

4

1.6

1.2

0.

7

5

1.0

0.8

0.

6

5

1.4

1.1

0.

7

6

0.9

0.7

0.

6

6

1.3

1.0

0.

6

7

0.9

0.7

0.

5

7

1.3

1.0

0.

6

8

0.9

0.7

0.

5

8

1.2

0.9

0.

6

9

0.8

0.6

0.

5

9

1.1

0.8

0.

5

10

0.7

0.6

0.

4

Hig

h

High

Med

Med

Lo

w

Low

10

1.0

0.8

0.

5

15

0.4

0.3

0.

2

0

1

2

3

4

5

6

7

0

1

2

3

4

5

6

7

15

0.5

0.4

0.

2

Getto orizzontale (m

)

H

V

e

l

o

c

i

t

à

d

e

l

l

'

a

r

4.

0

3.

0

2.

0

1.

0

0.

0

5

1.1

0.8

0.6

6

1.0

0.8

0.6

7

1.0

0.8

0.5

8

0.9

0.7

0.5

9

0.8

0.7

0.5

10

0.8

0.6

0.4

Hig

h

Me

d

Low

15

0.4

0.3

0.2

0

1

2

3

4

5

6

7

Getto orizzontale (m

)

Velocità dell’aria: Max. 4.6 m/s

Velocità dell’aria: Max

. 5.0 m/s

Med. 3.7 m/

s

Caratteristiche del ventilator

e

Min

. 2.8 m/s

MMK-UP0247HP(L)-

E

Distance Air speed MMK-AP0247HP-E

H

M

L

0

6.5

5.0

3.

1

1

3.8

2.9

1.

8

2

2.5

1.9

1.

2

3

1.8

1.4

0.

8

4

1.6

1.2

0.

7

5

1.4

1.1

0.

7

6

1.3

1.0

0.

6

7

1.3

1.0

0.

6

8

1.2

0.9

0.

6

9

1.1

0.8

0.

5

10

1.0

0.8

0.

5

0

1

2

3

4

5

6

7

15

0.5

0.4

0.

2

Getto orizzontale (m

)

Med. 3.9 m/

s

Min

. 2.8 m/s

MMK-UP0271HP-

E

Unità di misura: m/s

V

e

l

o

c

i

t

à

d

e

l

l

'

a

r

i

a

(

m

/

s

)

8.

0

7.

0

6.

0

5.

0

4.

0

3.

0

2.

0

1.

0

0.

0

Hig

h

Me

d

Low

V

e

l

o

c

i

t

à

d

e

l

l

'

a

r

i

a

(

m

/

s

)

8.

0

7.

0

6.

0

5.

0

4.

0

3.

0

2.

0

1.

0

0.

0

Hig

h

Med

Low

Distance Air speed MMK-AP0247HP-E

H

M

L

0

6.5

5.2

3.

6

1

3.8

3.0

2.

1

2

2.5

2.0

1.

4

3

1.8

1.4

1.

0

4

1.6

1.3

0.

9

5

1.4

1.1

0.

8

6

1.3

1.0

0.

7

7

1.3

1.0

0.

7

8

1.2

1.0

0.

7

9

1.1

0.9

0.

6

10

1.0

0.8

0.

6

0

1

2

3

4

5

6

7

15

0.5

0.4

0.

3

Getto orizzontale (m

)

Velocità dell’aria: Max.

Med.

Min

.

6.5 m/

s

5.0 m/

s

3.1 m/s

MMK-UP0301HP-E

Velocità dell’aria: Max

.

Med.

Min

.

6.5 m/

s

5.2 m/

s

3.6 m/

s

MMK-UP0361HP-E

Distance Air speed MMK-AP0187HP-

E

V

e

l

o

c

i

t

à

d

e

l

l

'

a

r

i

a

(

m

/

s

)

8.

0

7.

0

6.

0

5.

0

4.

0

3.

0

2.

0

1.

0

0.

0

0

7.5

6.6

5.5

1

4.7

4.1

3.4

2

3.4

3.0

2.5

3

2.7

2.4

2.0

4

2.3

2.0

1.7

5

2.0

1.8

1.5

6

1.8

1.6

1.3

7

1.6

1.4

1.2

8

1.5

1.3

1.1

9

1.3

1.1

0.9

10

1.0

0.9

0.7

High

Me

d

Low

V

e

l

o

c

i

t

à

d

e

l

l

'

a

r

i

a

(

m

/

s

)

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

Distance Air speed MMK-AP0157HP-

E

0

8.0

7.2

6.5

1

5.3

4.8

4.2

2

3.5

3.2

2.8

3

2.8

2.5

2.2

4

2.4

2.2

1.9

5

2.1

1.9

1.7

6

1.9

1.7

1.5

7

1.7

1.5

1.4

8

1.4

1.3

1.1

9

1.4

1.3

1.1

10

1.2

1.1

1.0

Hig

h

Med

Low

A

P

A

R

E

T

E

15

0.5

0.4

0.4

0

1

2

3

4

5

6

7

Getto orizzontale (m

)

15

0.5

0.5

0.4

0

1

2

3

4

5

6

7

Getto orizzontale (m)

Velocità dell’aria: Max.

Med.

Min

.

7.5 m/

s

6.6 m/

s

5.5 m/

s

Velocità dell’aria: Max

.

Med.

Min

.

8.0 m/

s

7.2 m/s

6.5 m/

s

Accessor

i

Tipo

Modello

RBM-PMV0361U-E

Applicabile ai modelli

A parete, da 0,3 a 1,25 H

P

Immagine

Kit PMV

Osservazion

i

Necessario prevedere una valvola per ogn

i

unità Parete senza valvola PVM a bord

o

RBM-PMV0961U-E

A parete, da 1,5 a 3,0 HP

CN60

CN61

CN8

0

Uscita segnale stato di funzionamento (raffrescamento,

riscaldamento, ventilatore, sbrinamento, funzione thermo ON

)

ON/OFF esterno, uscita modalità operativa

e uscita allarme

Thermo OFF e stop forzato unità interna in base

all’ingresso di segnale

137